Main
Features
:
-
Universal
Power Supply
-
Protections: Short
circuit , Overload
protections, Over voltage
-
Cooling by free air
convection
-
LED indicator for
power on
|
CNB3150617-00301-LVD certificate
CNB3150617-00428-EMC certificate
CNB3150617-00428-EMC test report
CTS-CNB3150617-00301-LVD test report |
Specification
|
S-120-12 |
S-120-12
|
S-120-15 |
S-120-24 |
S-120-48 |
Output
|
DC Voltage
|
5V |
12V
|
15V |
24V |
48V |
Rated Current
|
24A |
10A
|
8A |
5A |
2,5A |
Current Range
|
0 ~ 24A
|
0 ~ 10A
|
0 ~ 8A |
0
~ 5A |
0
~ 2,5A |
Rated Power
|
120W
|
Ripple &
Noise (max)
|
100 mVp-p |
125 mVp-p |
240 mVp-p |
Voltage
Adjustable Range
|
±
10% |
±
10%
|
±
10% |
±
10% |
±
10% |
Voltage
Tolerance
|
±
2% |
± 1%
|
Input
|
Voltage Range
|
100~120VAC
or 200~240VAC |
Frequency
Range
|
47 ~ 63 Hz |
Efficiency
|
78
% |
81 %
|
|
84 % |
Cold Start
|
30A on 115VAC, 60A
on 230VAC |
Protection
|
Over Load
|
105 ~ 150%
|
Fold back current
limiting
Recovers
automatically after fault
condition is removed
|
Environment
|
Ambient
Temperature
|
-10 ~
+60oC
|
Ambient
Humidity
|
20 ~ 90 %RH
non-condensing |
Storage Temperature
|
-20
~ +85oC
|
Storage Humidity
|
|
10 ~ 95 %RH non-condensing
|
|
|
|