Contact structure
|
M4 screw tightening terminal, 2 circuits
NO(connections 3 i 4) and
NC (connections 1 i 2)
|
Contact material
|
AgNi |
Protective structure
|
IP67 (Only when using our company product HYC-M2
in the wire opening) |
Rated current(le)
|
6 A 250 V a.c (AC-15, DC-13) |
Dielectric strength
|
2,000 V a.c 50/60 ㎐ for 1 min (between the
terminal and non-recharing metal part) |
Insulation resistance
|
Min 100 ㏁ (500 V d.c insulated ohmmeter) |
Contact resistance
|
Max 50 ㏁ (default value) |
Rated voltage(Ue)
|
250 V a.c, 30 V d.c |
Actuator intensity
|
5 times larger than O.F (force required to
operate) 1min to the, operating direction |
Vibration
|
Double amplitude 1.5mm, frequency 10 ~ 55 ㎐,
continuously 2 hour |
Shock
|
1,000 (durability), 300 ㎨ (malfunction) |
Allowable operation speed
|
0.1 ~ 1 m/s (without damaging the actuator) |
Life expectancy Mechanical |
Min 1million times (open/close frequency 120
times/min) |
Life expectancy Electrical |
Min 300 thousand times (open/close frequency 20
times/min) |
Ambient temperature |
-10 ~ 70
oC |
Ambient humidity |
45 ~ 95 % R.H. |
Weight |
Approx 350 g (included the box with HY-M904) |