SSR-40LA
|
20,0€
|
|
Load current
|
40A
|
Load voltage
|
90-250VAC
|
Control mode
|
Voltage regulator controll
|
Control current
|
DC 4~20mA
|
On voltage
|
≤1.5V
|
On leakage Current
|
≤4mA
|
On-off time
|
≤ 10mS
|
Dielectric Strength
|
2000VAC
|
Insulation Resistance |
500MΩ / 500VDC |
Ambient Temperature
|
-20~+70 oC
|
Working station indicator |
LED |
Weight |
115g |
|
HARDWARE SCHEME: |
|
OPERATION NOTICE: |
1. Resistive load could not exceed 60% of the rated current.
2. Inductive or capacitive load could not exceed 40% of the
rated current.
3. Electric machine load could not exceed 20% of the rated
current.
4. Proper radiator adapted to the working requirement of
solid state relay should be equipped, the allowance should
be
widened when the load radiating condition is not so good.
Short-circuit load is not allowable.
5. Over current protection: over current and short circuit
are the main reasons for permanent damage of output
controllable silicon in the SSR, and using fast fuse and air
switch is one of methods for over current protection, fuse
is
also available for small capacity.
6. Over voltage protection: It can adopt parallel
voltage-dependent resistance(MOV), the MOV area decides the
absorption power, while its thickness decides the protective
voltage value, generally, 471/10D voltage-dependent
resistance for 220V series SSR, 681/10D voltage-dependent
resistance for 380V series SSR, 821/10D
voltage-dependent resistance for 480V series SSR. |
Back To Top ▲
|
|